| Application & Ordering information |
|
1 、Application
HLC-4XQ04GG definite purpose contactors (4-pole ,40A ) are ideal for(HVAC) air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, lighting, pools & spas and food service equipment.
|
|
2 、Ordering information
|
|
HL
|
C
|
-
|
4X
|
Q
|
04
|
CG |
|
|
Hongli Electric
|
Contactors
|
Packaging
|
Pole Form
|
Coil Voltage
|
Contact Rating
|
Termination
|
|
|
"Y" :Individual Box Pack
|
4X : 4Pole
|
Q:24VAC
|
04: FLA 40A
|
CG: #14-4 Lug with dual QC
|
|
|
"-" :Factory Bulk Pack
|
|
|
Product Feature
|
Detailed Product Description
|
• Unique amortization system to eliminate contact bounce
|
|
• Low cost
|
|
• Accessories modification quickly and easily without using tools
|
|
• Various kinds of terminals for customers' special requirements
|
|
• Easy to change the coil
|
|
• General amounting size, easy for replacement
|
|
• Can be combined with a thermal overload relay to form an electromagnet starter to protect the line in which overload operation may occur
|
|
• Double E magnet assembly providing optimal performance with reduced power consumption
|
|
• Effective dustproof cover available
|
|
• Silver Cadmium Oxide contacts provide long electrical endurance.
|
|
• Class F high temperature insulated coils are standard.
|
|
|
Technology Data
|
NUMBER
OF
POLES
|
COIL
VOLTAGE
50/60HZ
|
FULL
LOAD
AMPS
|
LINE VOLTAGE
|
LOCKED ROTOR AMPS
|
RESISTIVE SMPS RATING
|
MAXIMUM HORSEPOWER
|
BOX QUANTITY
|
APPROX UNIT WEIGHT
|
|
VOLTAGE
|
SINGLE
PHASE
|
THREE
PHASE
|
|
20FLA-3POLE
|
|
3
|
24
110/120
280/240
277
|
20
|
240/277
480
600
|
120
100
80
|
30
30
30
|
110/120
200/240
480/600
|
1.5
3
-
|
-
7.5
7.5
|
25
|
.45 kg
|
|
25FLA-3POLE
|
|
3
|
24
110/120
280/240
277
|
25
|
240/277
480
600
|
150
125
100
|
35
35
35
|
110/120
200/208
240/277
480
600
|
2
-
5
-
-
|
-
7.5
10
25
20
|
25
|
.45 kg
|
|
30FLA-3POLE
|
|
3
|
24
24
110/120
110/120
208/240
208/240
277
|
30
|
240/277
480
600
|
180
150
120
|
40
40
40
|
110/120
200/208
240/277
480
600
|
2
-
5
-
-
|
-
10
10
15
20
|
25
|
.45 kg
|
|
40FLA-3POLE
|
|
3
|
24
24
110/120
110/120
208/240
208/240
277
|
40
|
240/277
480
600
|
240
200
160
|
50
50
50
|
110/120
200/208
240/277
480
600
|
3
-
7.5
-
-
|
-
10
10
20
25
|
25
|
.45 kg
|
OTHER SPECIFCATIONS
|
20-30 FLA
|
40 FLA
|
|
Line and Load Terminals
|
#10-32 screw*
|
Box Lug
|
|
Wire Size Awg Min-Max
|
16-8**
|
14-4 Cu/AL
|
|
Tightening Torque(Recommended)
|
22 in ibs
|
40 in ibs
|
|
Quick Connects:power Terminals Coil Termainals
|
Dual 250 QC
Dual 250 qc(2)***
|
Dual 250 QC
Dual 250 qc(2)***
|
|
Covers
|
Optional
|
Standard
|
|
Insulation System
|
130℃ Class B
|
130℃ Class B
|
|
*Stranding must be split for #8 wirt. **(1)#6-32 screw and (1).250QC are optional.***Permissible Ambient Temperature: -40℃/65℃ -40F/150F
|
|
COIL TECHNICAL DATA 50/60hz
|
HLC Series
|
|
Nominal Coil Voltage
|
24
|
120
|
208/240
|
277
|
480
|
|
Maximum Pickup Volts
|
18
|
88
|
177
|
220
|
384
|
|
Drop-Out Volts Range
|
6-15
|
20-70
|
40-140
|
65-185
|
150-270
|
|
Nominal Inrush VA@50Hz
|
65
|
65
|
65
|
65
|
65
|
|
Nominal Inrush VA@60Hz
|
60
|
60
|
60
|
60
|
60
|
|
Nominal Sealed VA@50Hz
|
7.5
|
7.5
|
7.5
|
7.5
|
7.5
|
|
Nominal Sealed VA@60Hz
|
6
|
6
|
6
|
6
|
6
|
|
Nominal DC Resistance-Ohms
|
6.6
|
165
|
660
|
880
|
1320
|
|
|
Deimensions
|
| |
|
Specification
|
|
HLC-1P,1N,1X,2X,3X,4X Series Definite Purpose Contactor DownLoad PDF DataSheet
|
|
|
|
|
|