| Application |
|
1 Application
HLC-3XV04CG definite purpose contactors (3-pole ,40A ) are ideal forHVAC air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, lighting, pools & spas and food service equipment.
|
|
2 Ordering information
|
| HL |
C |
- |
3X |
V |
04 |
CG |
|
| Hongli Electric |
Contactors |
Packaging
|
Pole Form
|
Coil Voltage
|
Contact Rating
|
Termination
|
|
| "Y" :Individual Box Pack |
3X : 3Pole |
V:277VAC |
04: FLA 40A |
CG: #14-4 Lug with dual QC |
|
| "-" :Factory Bulk Pack |
|
|
Product Feature
|
Detailed Product Description
|
Unique amortization system to eliminate contact bounce |
| Low cost |
| Accessories modification quickly and easily without using tools |
| Various kinds of terminals for customers' special requirements |
| Easy to change the coil |
| General amounting size, easy for replacement |
| Can be combined with a thermal overload relay to form an electromagnet starter to protect the line in which overload operation may occur |
| Double E magnet assembly providing optimal performance with reduced power consumption |
| Effective dustproof cover available |
| Silver Cadmium Oxide contacts provide long electrical endurance. |
| Class F high temperature insulated coils are standard. |
|
|
Technology Data
|
NUMBER
OF
POLES |
COIL
VOLTAGE
50/60HZ |
FULL
LOAD
AMPS |
LINE VOLTAGE |
LOCKED ROTOR AMPS |
RESISTIVE SMPS RATING |
MAXIMUM HORSEPOWER |
BOX QUANTITY |
APPROX UNIT WEIGHT |
| VOLTAGE |
SINGLE
PHASE |
THREE
PHASE |
| 20FLA-3POLE |
| 3 |
24
110/120
280/240
277 |
20 |
240/277
480
600 |
120
100
80 |
30
30
30 |
110/120
200/240
480/600
|
1.5
3
-
|
-
7.5
7.5
|
25 |
.45 kg |
| 25FLA-3POLE |
| 3 |
24
110/120
280/240
277 |
25 |
240/277
480
600 |
150
125
100 |
35
35
35 |
110/120
200/208
240/277
480
600
|
2
-
5
-
- |
-
7.5
10
25
20 |
25 |
.45 kg |
| 30FLA-3POLE |
| 3 |
24
24
110/120
110/120
208/240
208/240
277 |
30 |
240/277
480
600 |
180
150
120 |
40
40
40 |
110/120
200/208
240/277
480
600
|
2
-
5
-
- |
-
10
10
15
20 |
25 |
.45 kg |
| 40FLA-3POLE |
| 3 |
24
24
110/120
110/120
208/240
208/240
277 |
40 |
240/277
480
600 |
240
200
160 |
50
50
50 |
110/120
200/208
240/277
480
600
|
3
-
7.5
-
- |
-
10
10
20
25 |
25 |
.45 kg |
OTHER SPECIFCATIONS
|
20-30 FLA |
40 FLA |
| Line and Load Terminals |
#10-32 screw* |
Box Lug |
| Wire Size Awg Min-Max |
16-8** |
14-4 Cu/AL |
| Tightening Torque(Recommended) |
22 in ibs |
40 in ibs |
| Quick Connects:power Terminals Coil Termainals |
Dual 250 QC
Dual 250 qc(2)*** |
Dual 250 QC
Dual 250 qc(2)*** |
| Covers |
Optional |
Standard |
| Insulation System |
130 Class B |
130 Class B |
| *Stranding must be split for #8 wirt. **(1)#6-32 screw and (1).250QC are optional.***Permissible Ambient Temperature: -40/65 -40F/150F |
| COIL TECHNICAL DATA 50/60hz |
HLC Series |
| Nominal Coil Voltage |
24 |
120 |
208/240 |
277 |
480 |
| Maximum Pickup Volts |
18 |
88 |
177 |
220 |
384 |
| Drop-Out Volts Range |
6-15 |
20-70 |
40-140 |
65-185 |
150-270 |
| Nominal Inrush VA@50Hz |
65 |
65 |
65 |
65 |
65 |
| Nominal Inrush VA@60Hz |
60 |
60 |
60 |
60 |
60 |
| Nominal Sealed VA@50Hz |
7.5 |
7.5 |
7.5 |
7.5 |
7.5 |
| Nominal Sealed VA@60Hz |
6 |
6 |
6 |
6 |
6 |
| Nominal DC Resistance-Ohms |
6.6 |
165 |
660 |
880 |
1320 |
|
|
|
| |
|
Specification
|
|
HLC-1P,1N,1X,2X,3X,4X Series Definite Purpose Contactor DownLoad PDF DataSheet
|
|
|
|
|
|
|