1 Application
HLC-1PQ04GG definite purpose contactors (1-pole ,40A ) are ideal forHVAC air conditioning, refrigeration, heating, data processing, welding, elevators, hoists & cranes, lighting, pools & spas and food service equipment.
|
|
2 Ordering information
|
| HL |
C |
- |
1P |
Q |
04 |
GG |
|
| Hongli Electric |
Contactors |
Packaging
|
Pole Form
|
Coil Voltage
|
Contact Rating
|
Termination
|
|
| "Y" :Individual Box Pack |
1P : 1PNO Without Shunt |
U:24VAC |
04: FLA 40A |
GG: #14-4 Lug with quad QC |
|
| "-" :Factory Bulk Pack |
|
|
Product Feature
|
Detailed Product Description
|
Unique amortization system to eliminate contact bounce |
| Low cost |
| Accessories modification quickly and easily without using tools |
| Various kinds of terminals for customers' special requirements |
| Easy to change the coil |
| General amounting size, easy for replacement |
| Can be combined with a thermal overload relay to form an electromagnet starter to protect the line in which overload operation may occur |
| Double E magnet assembly providing optimal performance with reduced power consumption |
| Effective dustproof cover available |
| Silver Cadmium Oxide contacts provide long electrical endurance. |
| Class F high temperature insulated coils are standard. |
|
|
OTHER SPECIFCATIONS
|
20-35 FLA |
40 FLA |
| Line and Load Terminals |
#10-32Screw* |
BoxLugs* |
| Wire Size Awg Min-Max |
16-8* |
14-4Cu/Al |
| Tightening Torque(recommended) |
25in.Ibs |
40 in.Ibs |
| Coil Termination |
Dual.250 QC(2) |
Dual.250 QC(2) |
| Quick Connects.250 std.-1 or 11-2 Pole |
Quad |
Quad |
| Quick Connects.250 std.-2 Pole |
Dual or Quad |
Dual or Quad |
| Covers |
Optional |
Standard |
| Insulation System |
130 Class B |
130 Class B |
| *stranding must be split for #8 wire*Permissible Ambient Temperature: -40/65 -40F/150F |
| COIL TECHNICAL DATA 50/60hz |
1POLE CONTACTORS |
2POLE CONTACTORS |
| Nominal Coil Voltage |
24 |
120 |
208/240 |
277 |
24 |
120 |
208/240 |
277 |
| Maximum Pickup Volts |
18 |
88 |
177 |
221 |
18 |
88 |
177 |
221 |
| Drop-Out Volts Range |
6-15 |
20-70 |
40-140 |
50-165 |
6-15 |
20-70 |
40-140 |
50-160 |
| Nominal Inrush VA@50Hz |
31 |
31 |
35 |
31 |
22 |
22 |
22 |
22 |
| Nominal Inrush VA@60Hz |
28 |
28 |
32 |
28 |
20 |
20 |
20 |
20 |
| Nominal Sealed VA@50Hz |
6 |
6 |
7 |
6 |
5.5 |
5.5 |
5.5 |
5.5 |
| Nominal Sealed VA@60Hz |
5 |
5 |
6 |
5 |
4.5 |
4.5 |
4.5 |
4.5 |
| Nominal DC Resistance-Ohms |
17.5 |
450 |
1800 |
2252 |
13 |
275 |
1056 |
1772 |
|
|
Deimensions
|
| |
|
Specification
|
|
HLC-1P,1N,1X,2X,3X,4X Series Definite Purpose Contactor DownLoad PDF DataSheet
|
|
| |
|
| |
|
|
|
|
|